viii Symbol CS3000 Series Scanner Product Reference GuideEnable/Disable Codabar ...
4 - 34 Symbol CS3000 Series Scanner Product Reference GuideSet Lengths for Interleaved 2 of 5 Parameter # L1 = 0x16, L2 = 0x17The length of a code ref
Symbologies 4 - 35Set Lengths for Interleaved 2 of 5 (continued)Length Within Range - Select this option to decode only codes within a specified range
4 - 36 Symbol CS3000 Series Scanner Product Reference GuideI 2 of 5 Check Digit VerificationParameter # 0x31When enabled, this parameter checks the in
Symbologies 4 - 37Convert I 2 of 5 to EAN-13Parameter # 0x52This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the hos
4 - 38 Symbol CS3000 Series Scanner Product Reference GuideSet Lengths for Discrete 2 of 5 Parameter # L1 = 0x14, L2 = 0x15The length of a code refers
Symbologies 4 - 39Chinese 2 of 5Enable/Disable Chinese 2 of 5Parameter # 0xF0 0x98To enable or disable Chinese 2 of 5, scan the appropriate bar code b
4 - 40 Symbol CS3000 Series Scanner Product Reference GuideSet Lengths for CodabarParameter # L1 = 0x18, L2 = 0x19The length of a code refers to the n
Symbologies 4 - 41CLSI EditingParameter # 0x36Enable this to strip the start and stop characters and insert a space after the first, fifth, and tenth
4 - 42 Symbol CS3000 Series Scanner Product Reference GuideMSIEnable/Disable MSI Parameter # 0x0BTo enable or disable MSI, scan the appropriate bar co
Symbologies 4 - 43Set Lengths for MSIParameter # L1 = 0x1E, L2 = 0x1FThe length of a code refers to the number of characters (i.e., human readable cha
About This GuideIntroductionThe Symbol CS3000 Series Scanner Product Reference Guide provides general instructions for setting up, operating, maintain
4 - 44 Symbol CS3000 Series Scanner Product Reference GuideMSI Check DigitsParameter # 0x32These check digits at the end of the bar code verify the in
Symbologies 4 - 45MSI Check Digit AlgorithmParameter # 0x33If MSI Check Digits on page 4-44 is set to Two, an additional verification is required to e
4 - 46 Symbol CS3000 Series Scanner Product Reference GuideEnable/Disable GS1 DataBar Limited Parameter # 0xF0 0x53To enable or disable GS1 DataBar Li
Symbologies 4 - 47Convert GS1 DataBar to UPC/EANParameter # 0xF0 0x8DThis parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols. En
4 - 48 Symbol CS3000 Series Scanner Product Reference GuideNumeric Bar CodesFor parameters requiring specific numeric values, use the following bar co
Symbologies 4 - 49Numeric Bar Codes (continued)56789
4 - 50 Symbol CS3000 Series Scanner Product Reference GuideCancelIn case of an error or to change the selection, scan the bar code below.Cancel
Chapter 5 Maintenance and Technical SpecificationsIntroductionThis chapter provides suggested scanner maintenance, troubleshooting, and technical spec
5 - 2 Symbol CS3000 Series Scanner Product Reference GuideTroubleshooting Table 5-1 TroubleshootingProblem Possible Causes Possible SolutionsLaser
Maintenance and Technical Specifications 5 - 3Technical SpecificationsTable 5-2 Technical Specifications - ScannerItemDescriptionSymbol CS3000 Symb
xii Symbol CS3000 Series Scanner Product Reference Guide•Appendix C, Sample Bar Codes includes sample bar codes.Notational ConventionsThe following co
5 - 4 Symbol CS3000 Series Scanner Product Reference GuideMinimum Element Width 5 mil (0.127 mm) 7.5 mil (0.191 mm)Decode Ranges 4 mil: 0.9” - 4.9”5
Maintenance and Technical Specifications 5 - 5Decode ZoneIn .cm00CS30005 mil7.407.5 mil100% UPC12.4023.4025.4027.4031.40*055In .cmWidth ofField10 1001
5 - 6 Symbol CS3000 Series Scanner Product Reference Guide
Appendix A Standard Default ParametersTable A-1 Default Table ParameterParameter Number (Hex)Factory DefaultPage NumberUser PreferencesReset N/A3-
A - 2 Symbol CS3000 Series Scanner Product Reference GuideData OptionsTransmit Code ID Character 0x2D None3-17Prefix/Suffix ValuesPrefix Suffix 1Suff
Standard Default Parameters A - 3Convert UPC-E to A 0x25 Disable4-17Convert UPC-E1 to A 0x26 Disable4-17EAN-8 Zero Extend 0x27 Disable4-18Bookland ISB
A - 4 Symbol CS3000 Series Scanner Product Reference GuideInterleaved 2 of 5Interleaved 2 of 5 0x06 Enable4-33Set Length(s) for I 2 of 5 0x160x17144-3
Standard Default Parameters A - 5GS1 DataBar GS1 DataBar-14 0xF00x52Disable4-45GS1 DataBar Limited 0xF00x53Disable4-46GS1 DataBar Expanded 0xF00x54D
A - 6 Symbol CS3000 Series Scanner Product Reference Guide
Appendix B Programming ReferenceCode Type IDsTable B-1 Code Type IDsCode Type Hex Value Code Type Hex ValueNot Applicable 0x00 EAN-8 with 2 Supps.
About This Guide xiiiService InformationIf you have a problem with your equipment, contact Motorola Enterprise Mobility support for your region. Conta
B - 2 Symbol CS3000 Series Scanner Product Reference GuideSymbol Code IdentifiersTable B-2 Symbol Code CharactersCode Character Code TypeA UPC/EA
Programming Reference B - 3AIM Code IdentifiersEach AIM Code Identifier contains the three-character string ]cm where:] = Flag Character (ASCII 93)c =
B - 4 Symbol CS3000 Series Scanner Product Reference GuideThe modifier character is the sum of the applicable option values based on Table B-4.Table B
Programming Reference B - 5MSI 0 Check digits are sent.1 No check digit is sent.Example: An MSI bar code 4123, with a single check digit checked, is
B - 6 Symbol CS3000 Series Scanner Product Reference GuideGS1-128 (formerly UCC/EAN-128)GS1-128 is a convention for printing data fields with standard
Programming Reference B - 7Setting Prefixes and Suffixes To append a prefix and suffixes to the decode data:1. Set the Scan Data Transmission Format (
B - 8 Symbol CS3000 Series Scanner Product Reference Guide1024 18h $X CTRL X1025 19h $Y CTRL Y1026 1Ah $Z CTRL Z1027 1Bh %A CTRL [1028 1Ch %B CTRL \10
Programming Reference B - 91053 35h 5 51054 36h 6 61055 37h 7 71056 38h 8 81057 39h 9 91058 3Ah /Z :1059 3Bh %F ;1060 3Ch %G <1061 3Dh %H =1062 3Eh
B - 10 Symbol CS3000 Series Scanner Product Reference Guide1082 52h R R1083 53h S S1084 54h T T1085 55h U U1086 56h V V1087 57h W W1088 58h X X1089 59
Programming Reference B - 11Values from 1128 through 1255 may also be set. 1111 6Fh +O o1112 70h +P p1113 71h +Q q1114 72h +R r1115 73h +S s1116 74h +
xiv Symbol CS3000 Series Scanner Product Reference Guide
B - 12 Symbol CS3000 Series Scanner Product Reference Guide
Appendix C Sample Bar CodesUPC-AUPC-E012345 67890501234565
C - 2 Symbol CS3000 Series Scanner Product Reference GuideUPC-E1EAN-13EAN-8Code 39NOTE To enable this symbology in order to scan the sample, see Enabl
Sample Bar Codes C - 3Trioptic Code 39Code 93Code 11NOTE To enable this symbology in order to scan the sample, see Enable/Disable Trioptic Code 39 on
C - 4 Symbol CS3000 Series Scanner Product Reference GuideCodabarMSIInterleaved 2 of 5NOTE To enable this symbology in order to scan the sample, see E
IndexAAIM code identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . B-3modifier characters . . . . . . . . . . . . . . . . . . . . . . .
Index - 2 Symbol CS3000 Series Scanner Product Reference Guideconvert UPC-E to UPC-A . . . . . . . . . . . . . . 4-17convert UPC-E1 to UPC-A . . . .
Index - 3LLED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1charging . . . . . . . . . . . . . . . . . . . . . . .
Index - 4 Symbol CS3000 Series Scanner Product Reference Guide
Chapter 1 Getting StartedIntroductionThe Symbol CS3000 Series Scanner captures and stores bar codes for a variety of uses, and transmits bar code data
72E-136088-01 Revision A - June 2010Motorola, Inc.One Motorola PlazaHoltsville, New York 11742, USA1-800-927-9626http://www.motorola.com/enterprisemob
1 - 2 Symbol CS3000 Series Scanner Product Reference GuideUnpacking the ScannerRemove the scanner from its packing and inspect it for damage. If the s
Getting Started 1 - 3Charging the Scanner Battery To charge the CS3000 series scanner, connect it to a host PC via the USB host cable or charging crad
1 - 4 Symbol CS3000 Series Scanner Product Reference GuideThe scanner begins charging. A complete charge of a fully discharged battery takes approxima
Getting Started 1 - 5Scanner Charging LEDThe scanner’s LED indicates charging activity (see Table 2-1 on page 2-3). The amber LED blinks slowly during
1 - 6 Symbol CS3000 Series Scanner Product Reference GuideBluetooth Connection ExamplesThis section provides the following connection examples:•PC HID
Getting Started 1 - 74. Place the application into discover Bluetooth device mode (in this example, select the check box), and click Next. Figure 1-9
1 - 8 Symbol CS3000 Series Scanner Product Reference Guide6. Select an option, then click Next:•If you select Choose a passkey for me, the host genera
Getting Started 1 - 98. Click Finish to complete the pairing. The device appears in the Bluetooth Devices window.Figure 1-12 Bluetooth Devices Wind
1 - 10 Symbol CS3000 Series Scanner Product Reference Guide3. On the host PC, launch the third party Bluetooth pairing application. Following is a sam
Getting Started 1 - 115. Select the CS3070 device from the discovered device list. The Bluetooth application may prompt you to scan a passkey it gener
1 - 12 Symbol CS3000 Series Scanner Product Reference Guide7. Click Finish. In order to complete the pairing, open a serial input application such as
Getting Started 1 - 134. Tap Add new device... The ES400 searches for Bluetooth devices.Figure 1-18 Sample Device Discovery Window5. Select the C
1 - 14 Symbol CS3000 Series Scanner Product Reference Guide7. If you entered a passcode in Step 6, scan Numeric Bar Codes for PIN Entry on page 1-21 c
Getting Started 1 - 159. Select the device and tap Connect to complete the pairing. The device appears in the Connected list, and the CS3070 issues a
Symbol CS3000 Series ScannerProduct Reference Guide72E-136088-01June 2010
1 - 16 Symbol CS3000 Series Scanner Product Reference Guide3. On the ES400, launch the third party Bluetooth pairing application. Following is a sampl
Getting Started 1 - 175. Select the CS3070 device from the discovered device list and tap Next. The device prompts you to enter a passcode.Figure 1-25
1 - 18 Symbol CS3000 Series Scanner Product Reference Guide6. Enter the CS3070 default PIN (1234) and tap Next.Figure 1-26 Connection Verification
Getting Started 1 - 198. Select the device and tap Connect. The Partnership Settings window appears.Figure 1-28 Partnership Settings Window9. Tap
1 - 20 Symbol CS3000 Series Scanner Product Reference GuideUnpairingTo temporarily unpair the scanner and host, press the Bluetooth button. This disab
Getting Started 1 - 21Numeric Bar Codes for PIN EntryUse the following bar codes for pin entry for Bluetooth connection.0123456789Enter
1 - 22 Symbol CS3000 Series Scanner Product Reference GuideConfiguring the ScannerTo configure the scanner for initial use:1. Scan the parameter bar c
Getting Started 1 - 23Editing the Configuration FileUse a text editor such as Notepad to set configuration values in the Config.ini editable text file
1 - 24 Symbol CS3000 Series Scanner Product Reference GuideScanParam Variable Any scan engine parameter. Multiple entries are allowed. Sent after rese
Chapter 2 ScanningIntroductionThis chapter provides instructions for how to scan bar codes and send the data to a host. Beeper and LED definitions are
ii Symbol CS3000 Series Scanner Product Reference Guide© 2010 by Motorola, Inc. All rights reserved.No part of this publication may be reproduced or u
2 - 2 Symbol CS3000 Series Scanner Product Reference Guide4. The scanner beeps and the LED turns green to indicate a successful decode. See Table 2-1
Scanning 2 - 3Out of Range BehaviorIf the scanner moves out of range of the host and does not re-pair with the host within the timeout period, it stor
2 - 4 Symbol CS3000 Series Scanner Product Reference GuideToggle data protection on or off(when enabled)Press & hold both scan (+) and delete (-)
Scanning 2 - 5Beeper IndicationsData protection (enabled and on) Scan/function/ host comRapidly flashing redUnexpected failure Scan/function/dock Fla
2 - 6 Symbol CS3000 Series Scanner Product Reference Guide
Chapter 3 User PreferencesIntroductionThis chapter describes each user preference feature and provides the programming bar codes for selecting these f
3 - 2 Symbol CS3000 Series Scanner Product Reference GuideUser Preferences Default ParametersTable 3-1 lists the defaults for user preference paramete
User Preferences 3 - 3Send Bluetooth Version N/A3-21Send Scan Engine Version N/A3-21Save ConfigurationN/A3-22Table 3-1 User Preferences Default Ta
3 - 4 Symbol CS3000 Series Scanner Product Reference GuideResetTo reset the scanner and apply parameters from the configuration file, scan the followi
User Preferences 3 - 5Set Date and TimeSet DateScan the Set Date bar code, then scan six numeric digits in the format mmddyy from Numeric Bar Codes fo
iiiRevision HistoryChanges to the original manual are listed below:Change Date Description-01 Rev A 06/2010 Initial release
3 - 6 Symbol CS3000 Series Scanner Product Reference GuideNumeric Bar Codes for Date and Time Settings0123456789Enter
User Preferences 3 - 7Clear DataScan the following bar code to clear all batch bar code data on the scanner. This deletes the BarcodeFile.txt from the
3 - 8 Symbol CS3000 Series Scanner Product Reference GuideBeeper SettingsBeeper VolumeParameter # 0x8CTo select a decode beep volume, scan the appropr
User Preferences 3 - 9Beeper ToneParameter # 0x91To select a decode beep frequency (tone), scan the appropriate bar code.Low Frequency(0x02)*Medium Fr
3 - 10 Symbol CS3000 Series Scanner Product Reference GuideMute BeeperScan the Mute Beeper bar code to mute the beeper.Mute Beeper(0x01)*Do Not Mute B
User Preferences 3 - 11Scanner OptionsScan AngleParameter # 0xBFThis parameter sets the scan angle to narrow or wide.Narrow Angle (35°)(0x05)*Wide Ang
3 - 12 Symbol CS3000 Series Scanner Product Reference GuideTransmit “No Read” MessageParameter # 0x5EEnable this option to transmit “NR” if a symbol d
User Preferences 3 - 13Bluetooth OptionsBluetooth UnpairScan the following bar code to unpair the scanner from the host.UnpairBluetooth HID ProfileSca
3 - 14 Symbol CS3000 Series Scanner Product Reference GuideDisable All SymbologiesScan the bar code below to disable the decoding of all symbologies.
User Preferences 3 - 15Linear Code Type Security LevelParameter # 0x4EThe scanner offers four levels of decode security for linear code types (e.g., C
iv Symbol CS3000 Series Scanner Product Reference Guide
3 - 16 Symbol CS3000 Series Scanner Product Reference GuideLinear Security Level 3The scanner must read code types other than the following twice befo
User Preferences 3 - 17Data OptionsTransmit Code ID CharacterParameter # 0x2DA code ID character identifies the code type of a scanned bar code. This
3 - 18 Symbol CS3000 Series Scanner Product Reference GuidePrefix/Suffix ValuesParameter # P = 0x69, S1 = 0x68, S2 = 0x6AAppend a prefix and/or one or
User Preferences 3 - 19Scan Data Transmission FormatParameter # 0xEBTo change the Scan Data Transmission Format, scan one of the following bar codes c
3 - 20 Symbol CS3000 Series Scanner Product Reference GuideScan Data Transmission Format (continued)<PREFIX> <DATA >(0x04)<PREFIX> &
User Preferences 3 - 21Send VersionsFirmware VersionScan the following bar code to send the firmware version to the host.Firmware VersionBluetooth Ver
3 - 22 Symbol CS3000 Series Scanner Product Reference GuideSave ConfigurationScan the following bar code after setting parameters to save the new conf
Chapter 4 SymbologiesIntroductionThis chapter describes symbology features and provides the programming bar codes for selecting these features for the
4 - 2 Symbol CS3000 Series Scanner Product Reference GuideSymbology Default ParametersTable 4-1 lists the defaults for all symbologies parameters. To
Symbologies 4 - 3Code 128Code 128 0x08 Enable4-21GS1-128 (formerly UCC/EAN-128) 0x0E Enable4-22ISBT 128 0x54 Enable4-22Code 39 Code 39 0x00 Enable4-23
Table of ContentsAbout This GuideIntroduction...
4 - 4 Symbol CS3000 Series Scanner Product Reference GuideDiscrete 2 of 5Discrete 2 of 5 0x05 Disable4-37Set Length(s) for D 2 of 5 0x140x15124-38Chin
Symbologies 4 - 5UPC/EANEnable/Disable UPC-AParameter # 0x01To enable or disable UPC-A, scan the appropriate bar code below.*Enable UPC-A(0x01)Disable
4 - 6 Symbol CS3000 Series Scanner Product Reference GuideEnable/Disable UPC-E1Parameter # 0x0CTo enable or disable UPC-E1, scan the appropriate bar c
Symbologies 4 - 7Enable/Disable EAN-13Parameter # 0x03To enable or disable EAN-13, scan the appropriate bar code below.*Enable EAN-13(0x01)Disable EAN
4 - 8 Symbol CS3000 Series Scanner Product Reference GuideDecode UPC/EAN SupplementalsParameter # 0x10Supplementals are bar codes appended according t
Symbologies 4 - 9Decode UPC/EAN Supplementals (continued)Select the desired option by scanning one of the following bar codes.Decode UPC/EAN Supplemen
4 - 10 Symbol CS3000 Series Scanner Product Reference GuideDecode UPC/EAN Supplementals (continued)Enable 977 Supplemental Mode(0x07)Enable 414/419/43
Symbologies 4 - 11Decode UPC/EAN Supplementals (continued)Supplemental User-Programmable Type 1(0x09)Supplemental User-Programmable Type 1 and 2(0x0A)
4 - 12 Symbol CS3000 Series Scanner Product Reference GuideUser-Programmable SupplementalsSupplemental 1: Parameter # 0xF1 0x43Supplemental 2: Paramet
Symbologies 4 - 13Transmit UPC-A Check DigitParameter # 0x28Scan the appropriate bar code below to transmit the symbol with or without the UPC-A check
vi Symbol CS3000 Series Scanner Product Reference GuideBeeper Indications ...
4 - 14 Symbol CS3000 Series Scanner Product Reference GuideTransmit UPC-E1 Check DigitParameter # 0x2AScan the appropriate bar code below to transmit
Symbologies 4 - 15UPC-E PreambleParameter # 0x23Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-E symbol.
4 - 16 Symbol CS3000 Series Scanner Product Reference GuideUPC-E1 PreambleParameter # 0x24Preamble characters (Country Code and System Character) can
Symbologies 4 - 17Convert UPC-E to UPC-AParameter # 0x25Enable this parameter to convert UPC-E (zero suppressed) decoded data to UPC-A format before t
4 - 18 Symbol CS3000 Series Scanner Product Reference GuideEAN Zero ExtendParameter # 0x27When enabled, this parameter adds five leading zeros to deco
Symbologies 4 - 19Bookland ISBN FormatParameter # 0xF1 0x40If you enabled Bookland EAN using Enable/Disable Bookland EAN on page 4-7, select one of th
4 - 20 Symbol CS3000 Series Scanner Product Reference GuideUPC/EAN Security LevelParameter # 0x4DThe Symbol CS3070 offers four levels of decode securi
Symbologies 4 - 21UCC Coupon Extended CodeParameter # 0x55The UCC Coupon Extended Code is an additional bar code adjacent to a UCC Coupon Code. To ena
4 - 22 Symbol CS3000 Series Scanner Product Reference GuideEnable/Disable GS1-128 (formerly UCC/EAN-128)Parameter # 0x0ETo enable or disable GS1-128,
Symbologies 4 - 23Code 39Enable/Disable Code 39Parameter # 0x00To enable or disable Code 39, scan the appropriate bar code below.*Enable Code 39(0x01)
Table of Contents viiEnable/Disable Bookland EAN ... 4-7Decode UPC/EAN Su
4 - 24 Symbol CS3000 Series Scanner Product Reference GuideConvert Code 39 to Code 32 (Italian Pharma Code)Parameter # 0x56Code 32 is a variant of Cod
Symbologies 4 - 25Set Lengths for Code 39Parameter # L1 = 0x12, L2 = 0x13The length of a code refers to the number of characters (i.e., human readable
4 - 26 Symbol CS3000 Series Scanner Product Reference GuideCode 39 Check Digit VerificationParameter # 0x30Enable this feature to check the integrity
Symbologies 4 - 27Enable/Disable Code 39 Full ASCIIParameter # 0x11Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the ful
4 - 28 Symbol CS3000 Series Scanner Product Reference GuideCode 93Enable/Disable Code 93Parameter # 0x09To enable or disable Code 93, scan the appropr
Symbologies 4 - 29Two Discrete Lengths - Select this option to decode only codes containing two selected lengths. For example, select Code 93 Two Disc
4 - 30 Symbol CS3000 Series Scanner Product Reference GuideCode 11Enable/Disable Code 11Parameter # 0x0ATo enable or disable Code 11, scan the appropr
Symbologies 4 - 31Set Lengths for Code 11 (continued)Code 11 - One Discrete LengthCode 11 - Two Discrete LengthsCode 11 - Length Within RangeCode 11 -
4 - 32 Symbol CS3000 Series Scanner Product Reference GuideCode 11 Check Digit VerificationParameter # 0x34This feature allows the scanner to check th
Symbologies 4 - 33Transmit Code 11 Check DigitsParameter # 0x2FThis feature selects whether or not to transmit the Code 11 check digit(s).Transmit Cod