Motorola LD-W-1 Spécifications Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
English LD-G-1 / LD-W-1
Page 38
Restrictions in Motorola I format
In Motorola I Format the following settings can be made:
§ Address, starting and maximum velocity
§ assignment of the funciton outputs to „function“
A reset and reading the address is not possible. It is not possible to
program the second velocity characteristic or the acceleration and brake
delay. The functions F1 to F4 cannot be switched.
Technical specifications
Data format Motorola II
Supply voltage 12-24 Volt digital voltage
Current consumption
(without connected loads) approx. 10 mA
Max. current for motor 1.000 mA
Max. current per function output 500 mA
Max. total current 1.500 mA
Protected to IP 00
Ambient temperature in use 0 - + 60° C
Ambient temperature in storage -10 - + 80° C
Comparative humidity allowed max. 85 %
Dimensions approx. 16,8 x 24 x 4,5 mm
Weight approx. 2 g
Checking the package contents
Check the contents of the package for completeness immediately after
unpacking:
§ one decoder, with or without soldered connecting wires, depending
on the version,
§ one manual.
N.B. For technical reasons it is possible that the PCB is not completely
inserted. This is not a fault.
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 35 36

Commentaires sur ces manuels

Pas de commentaire