MPC562BC 10/31/02
13
CAN_PORT Termination Options
The RA1-3 option locations provide the CAN_PORT with the ability to add bias and/or termination resistance. RA1 location
provides low bias (to ground) on the CAN Hi signal. RA3 location provides high bias (to +5V) on the CAN Low signal. RA2
location is 120 Ohms by default and provides termination between the respective CAN Port CAN Hi and CAN Low signals.
PWR Jack, Power Port and Power Oak Supply
The Motorola MPC5xx Oak series companion power supply Power Oak (PC33394) is provided on the MPC562BC board. This
device provides many features designed for automotive application but may also be useful for industrial or general purpose
applications. See the PC33394 data sheet on the support CD for full description of features, operation, and capability.
The Power Oak provides a regulated switch mode power source for the 2.6V, 3.3V, and 5V supplies on the EVB board. The basic
application of the Power Oak provides the Reset signals, back-up supplies for the KAPWR and IRAMSTBY to the MPC562, and the
CAN A port transceiver. Options are available on the board and some under software control via the MPC566 QSPI port to modify
the Power Oak application.
The Power Port provides tap points for the power supply outputs from the Power Oak. Following is the Power Port pin assignment:
Power Port Connections
PIN SIGNAL
1 +VIN DC supply
2+5V
3 +3.3V
4 +2.6V
5GND
Refer to Power Oak document for application of the provided power sources.
ON Option
The ON option provides a constant enable to the VIGN signal so the Power Oak is enabled upon power application. The ON option
maybe opened by cutting the trace between the 2 option pads on the top side of the board. This will allow application of the VIGN
signal externally with a switch or other source. Basic operation of the VIGN signal is to apply +VIN to enable the Power Oak
supplies.
PWR Jack
PWR jack connection provides power input from the supplied wall plug power source. Typical input is +12VDC. The PWR jack
provides a center positive terminal and ground outside sleeve. The jack accepts 2.1mm inside x 5.5mm outside power plugs.
PWR Front View
2mm Center Pin, Positive Volt
5.5mm Outer Ring, Ground
Vue de la page 12