Quick Reference Guide 15
Fix the cable to existing cable runs inside the electric lift truck using
cable ties, but make sure they are away from any moving or hot sur-
faces.
If the VC6090 needs to be re-positioned, be sure there is enough slack
in the cable to accommodate movement without putting tension on the
cable.
DO NOT wind a cable in and out of the mesh on a cage.
DO NOT route the cables on the outside of the electric lift truck or
areas where the electric lift truck may come in contact with objects.
Mounting the VC6000 Series on Gas/Diesel-Powered
Vehicles
Direct 10V to 33Vdc, with ignition sense for gas/diesel-powered lift trucks
and vehicles with 12V or 24V battery.
Connecting the Vehicle Power Cable
To connect the power cable:
1. Disconnect the power terminals from the vehicle battery.
2. Connect the black wire to the vehicle’s negative power source.
3. Connect the green wire to the vehicle’s ignition switch.
WARNING: Shortening or modifying the cable and/or by-passing
the in-line fuse voids the product warranty, nullifies the
product UL safety mark, and may result in a hazardous
condition. Do not modify the cable under any circum-
stance.
CAUTION DO NOT install the VC6000 series in a vehicle with a
positive ground electrical system.
WARNING: Failure to disconnect the battery before installing the
power converter may result in the injury or death of the
installer by electric shock.