Motorola CPCI-6115 Manuel de service Page 116

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 174
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 115
CPX8216 and CPX8216T Installation and Use (6806800A52C)
Chapter 9 Subassembly Removal and Installation
96
Alarm Panel Removal and Installation (Hot Swap)
The alarm panel is hot swappable—it can be removed from a live chassis without affecting
system functions or performance, or the function of the alarm panel itself.
Removal
Refer to the next figure and follow these steps to remove the alarm panel from the chassis:
1. Loosen the two captive screws at the top of the alarm panel.
2. Pull the top of the alarm panel away from the chassis. You may need to pull the two captive
screws to assist you.
3. Guide the two tabs at the bottom of the alarm panel out of their slots in the chassis.
4. Remove the alarm cable by pushing the two retaining clips out. This forces the connector off of
the header.
Note The critical alarm is a normally closed relay. If the alarm panel is connected to remote
alarm monitoring equipment, removing the system alarm cable may result in a critical alarm
report.
2407 9810
Alarm Panel
Vue de la page 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 173 174

Commentaires sur ces manuels

Pas de commentaire