6
CPX8216 and CPX8216T Installation and Use (6806800A52C)
45
6 Chassis Operations
Overview
This chapter provides the basic operating procedures for the CPX8216 chassis. For software-
specific information or information regarding the operation of third-party and add-on
components, please refer to the product’s vendor documentation. This chapter covers the
following major topics:
■ Recommended Power-On Procedures
■ Recommended Power-Off Procedure
■ Emergency Power-Off Procedure
■ Controls and Indicators
■ Setting the Chassis ID on the CPX8216T
■ Chassis Cooling
■ Power Monitoring
Recommended Power-On Procedures
Follow this procedure to power-on your chassis.
1. Verify that all chassis modules and associated data and control cables are properly configured
and installed.
2. Verify that the chassis configuration’s current loads do not exceed the power supplies’ limits.
The maximum current load of the chassis depends upon the configuration of the chassis and
can be determined from the following table which shows the single power supply output.
3. Verify that the chassis is connected to the AC or DC input power.
Voltage Regulation Minimum Load
Maximum
Load*
+5V ±3% 0.0A 40.0A
+3.3V ±3% 0.0A 40.0A
+12V ±5% 0.0A 10.4A
−12V ±5% 0.0A 4.0A
*Total combined output loading not to exceed 400W.
Commentaires sur ces manuels