Motorola CPCI-6115 Manuel de service Page 97

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 196
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 96
MOTLoad Firmware
CPCI-6200 Installation and Use (6806800J66C)
97
All devices that are available to MOTLoad for validation/verification testing are represented by
a unique device path string. Most MOTLoad tests require the operator to specify a test device
at the MOTLoad command line when invoking the test.
A listing of all device path strings can be displayed through the devShow command. If an SBC
device does not have a device path string, it is not supported by MOTLoad and cannot be
directly tested. There are a few exceptions to the device path string requirement, like testing
RAM, which is not considered a true device and can be directly tested without a device path
string. Refer to the devShow command description page in the MOTLoad Firmware Package
User’s Manual.
Most MOTLoad tests can be organized to execute as a group of related tests (a test suite)
through the use of the testSuite command. The expert operator can customize their
testing by defining and creating a custom testSuite(s). The list of built-in and user-defined
MOTLoad testSuites, and their test contents, can be obtained by entering testSuite -
dtestSuite at the MOTLoad prompt. All testSuites that are included as part of a product
specific MOTLoad firmware package are product specific. For more information, refer to the
command description page in the MOTLoad Firmware Package User’s Manual.
Test results and test status are obtained through the testStatus, errorDisplay and
taskActive commands. For more information, refer to the appropriate command
description page in the MOTLoad Firmware Package User’s Manual.
5.7 Using MOTLoad
Interaction with MOTLoad is performed via a command line interface through a serial port on
the SBC, which is connected to an X-terminal or other terminal emulator (for example,
Window’s Hypercomm). The default MOTLoad serial port settings are: 9600 baud, 8 bits, no
parity.
5.7.1 Command Line Interface
The MOTLoad command line interface is similar to a UNIX command line shell interface.
Commands are initiated by entering a valid MOTLoad command (a text string) at the MOTLoad
command line prompt and pressing the carriage-return key to signify the end of input.
MOTLoad then performs the specified action. An example of a MOTLoad command line
prompt is shown below. The MOTLoad prompt changes according to what product it is used on
(for example, HXEB100, CPCI6200, MVME5500).