2. Turn OFF the MW 800 via the OS. Note that in order to turn ON the MW 800, the
ignition key should be turned to OFF position, and switched back to ON.
Turning On the MW 800
Before powering ON the MW 800:
Verify proper display to CPU cable connection on both sides.
Verify keyboard connection to the display.
Verify that the vehicle power system can supply at least 15 Amps.
Check that the power cables are plugged into the power connectors of the CPU box and the
display.
Switch ON the main power switch (MAIN SWITCH) on the back panel of the CPU box.
If the MW 800 is connected through the ignition switch, insert the car key into the ignition
switch and rotate it to ACC position, or start the engine, before powering ON.
To power the workstation, press the Power button on the front panel of the CPU box, or press
the Workstation Power button on the display.
Turning Off the MW 800
To turn Off the workstation, press the CPU box or display Power button momentarily. The
workstation displays the Windows shut-down dialog box. Remember to save important
information before turning OFF the MW 800.
The MW 800 automatically turns OFF as a result of the following events:
Extreme temperatures
Discharged vehicle battery
Pressing the Power button on the CPU box or display for more than six seconds
In critical conditions or during maintenance, the workstation may be powered OFF by
turning the main power switch on the CPU box back panel.
Replacing Power Cable Fuse (Vehicle Power)
Remove the fuse (15A) from the fuse holder located on the Motorola DC cable and replace it
with a new one of the same type and value (part no. 6580283E06).
The main power switch on the CPU box back panel (MAIN SWITCH) must
be in OFF position before connecting to power supply source.
Note
Turning OFF the main power switch or disconnecting the power cable
when the MW 800 is running may seriously damage your operating
system or your hard disk.
!
Caution