Motorola MVME2400 Series Manuel de service Page 236

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 354
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 235
3-50 Computer Group Literature Center Web Site
System Memory Controller (SMC)
3
Error Logger Register
elog
When set, elog indicates that a single- or a multiple-bit
error has been logged by the SMC. If elog
is set by a
multiple-bit error, then no more errors will be logged until
software clears it. If elog
is set by a single-bit error, then
no more single-bit errors will be logged until software
clears it, however if elog
is set by a single-bit error and a
multiple-bit error occurs, the multiple-bit error will be
logged and the single-bit error information overwritten.
elog
can only be set by the logging of an error and cleared
by the writing of a one to itself or by power-up reset.
escb escb indicates the entity that was accessing SDRAM at the
last logging of a single- or multiple-bit error by the SMC.
If escb is 1, it indicates that the scrubber was accessing
SDRAM. If escb is 0, it indicates that the PowerPC 60x
bus master was accessing SDRAM.
esen
When set, esen allows errors that occur during scrubs to
be logged. When cleared, esen
does not allow errors that
occur during scrubs to be logged.
embt embt is set by the logging of a multiple-bit error. It is
cleared by the logging of a single-bit error. It is undefined
after power-up reset. The syndrome code is meaningless
if its embt bit is set.
ADDRESS
$FEF80030
BIT
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
NAME
elog
0
0
0
escb
esen
embt
esbt
ERR_SYNDROME
0
esblk0
esblk1
esblk2
0
0
0
scof
SBE_COUNT
OPERATION
R/C
R
R
R
R
R/W
R
R
READ ONLY
R
R
R
R
R
R
R
R/C
READ/WRITE
RESET
0 P
X
X
X
0 P
0 PL
0 P
0 P
0P
X
0P
0P
0P
X
X
X
0 P
0P
Vue de la page 235