INSTALLATION MANUAL DCH70 Installation Manual DCH70MESSAGEPOWER
1 INTRODUCTION 2 Features Tuner • Digital MPEG-2 main profile main level video processor • Provides an out-of-band (OOB) control channel Standard
1 INTRODUCTION 3 If You Need Help If you need assistance while working with the DCH70, contact the Motorola Technical Response Center (TRC): • Ins
5 2 OVERVIEW Front Panel 1 Power Indicator — Lit when the unit is powered ON, unlit when unit is OFF 2 Message Indicator* — Lit when a new messag
2 OVERVIEW 6 Rear Panel 1 RF In — Connects to cable signal from your service provider 2 RF Out — Ch 3/4 modulated audio/video (SDTV) to TV or VC
7 3 INSTALLATION Before You Begin Before you move or change components on the subscriber entertainment system: • Review the installation instructi
3 INSTALLATION 8 Audio Connection Options Connect the stereo audio cable to the AUDIO L and R connectors on the DCH70 and the audio left and right
3 INSTALLATION 9 Cabling to a Standard-Definition TV and an A/V Receiver Figure 3-1 Cabling to a Standard-Definition stereo TV Because some entert
3 INSTALLATION 10 Cabling to a Standard-Definition TV and Audio Receiver To connect to an audio receiver, such as a home mini system, follow a dais
3 INSTALLATION 11 Operational Check for the Remote Control The operational check tests communication with the remote control: Table 3-1 Operational
13 4 DIAGNOSTICS Diagnostics are displayed on the on-screen display (OSD). They confirm proper installation, including: • Checking error states a
4 DIAGNOSTICS 14 • Press cursor ◄, cursor ►, SELECT, or ENTER to execute the selected diagnostic. • To exit the diagnostic mode, press POWER on t
4 DIAGNOSTICS 15 Field Description disconnects the set-top E 10 SERIALNO Invalid serial number Not used E 11 INVALID UNIT ADDRESS Invalid unit
4 DIAGNOSTICS 16 Out-Of-Band (OOB) Status This diagnostic indicates the status of the out-of-band control channel. The Out-Of-Band Status fields
4 DIAGNOSTICS 17 Field Description Hunt Mode The state of OOB stream acquisition OSD Description None The set-top is locked to an OOB carrier
4 DIAGNOSTICS 18 3. After selecting the desired new frequency, the operator will press the SELECT key to start the search. The manual frequency se
4 DIAGNOSTICS 19 In-Band Status This diagnostic displays the in-band status for the last attempted channel tune. The In-Band Status fields are:
4 DIAGNOSTICS 20 Field Description OSD Description ”*” Data received blank No data received Carrier Lock Indicates whether the digital in-ba
4 DIAGNOSTICS 21 Audio/Video Status This diagnostic displays the audio and video status for the tuned channel. Field Description ADP Lock The A
i IMPORTANT SAFETY INSTRUCTIONS • Read these instructions. • Keep these instructions. • Heed all warnings. • Follow all instructions. • Do not
4 DIAGNOSTICS 22 OSD Description N/A The audio mode is not applicable to the currently tuned stream. Mono The audio mode is monophonic. St
4 DIAGNOSTICS 23 Unit Address This diagnostic displays the 16-digit (40-bit) unit address of the set-top. The Unit Address fields are: Field Desc
4 DIAGNOSTICS 24 Separable Security This diagnostic displays information on the inserted M-CARD and CableCARD Interface with the DCH. Field Descri
4 DIAGNOSTICS 25 Field Description set to ‘Unknown’ if the headend message was not received MSO Phone Number MSO Phone Number, as configured at th
4 DIAGNOSTICS 26 Field Description SP Lists the firmware version, as well as the patch release version number CableCARD The firmware version number
4 DIAGNOSTICS 27 The Current Channel status fields are: Field Description Connected State A connect or disconnect message determines whether the se
4 DIAGNOSTICS 28 Renewable Security The renewable security system includes a TVPC card that returns the security status to current. The Renewable
4 DIAGNOSTICS 29 Upstream Modem This diagnostic displays the upstream status and operating parameters. The RF Modem fields are: Field Description
4 DIAGNOSTICS 30 Last Poll Ack. Indicates the sequence number of the last poll acknowledge received by the set-top. The time stamp of the last pol
4 DIAGNOSTICS 31 Field Description Status The object status modes available are: • LOADING • DELETED • ENABLING • ENABLED • DSABLNG • DISAB
ii DURING INSTALLATION • Do not place the cable terminal in an enclosed area where the cooling vents are blocked or impede the flow of air throug
4 DIAGNOSTICS 32 Interactive Status This diagnostic tool gathers data about your system. The Interactive Status fields are: Field Description IP
4 DIAGNOSTICS 33 Field Description WAIT_SO_ACK The set-top is in the interactive initialization state and waiting for a Sign On acknowledgement.
4 DIAGNOSTICS 34 MAC Frequency Table The set-top uses a range of frequencies set by the host for upstream communications. The MAC Frequency Table d
4 DIAGNOSTICS 35 Message Types This diagnostic lists message types, IDs, and counts. Field Description Msg The message type Id The low order byt
4 DIAGNOSTICS 36 In-band Program Map Table (PMT) This diagnostic displays the Program Map Table information (For Motorola use only). Task Status T
4 DIAGNOSTICS 37 In-band Multicast Address Filter This diagnostic displays in-band multicast filter information. Field Description Filter Table:
4 DIAGNOSTICS 38 Connected Home Status This diagnostic displays information related to the Home Network of which the set-top is a part. This diagno
4 DIAGNOSTICS 39 Field Description Connected Home Table The Connected Home Table contains information related to each device connected to the set-t
4 DIAGNOSTICS 40 Keyboard / LED This diagnostic verifies the functionality of the front panel and the front-panel keypad. Each highlighted characte
41 5 TROUBLESHOOTING Troubleshooting guidelines follow. If problems still occur after performing the diagnostics, call the TRC for assistance, as d
iii FCC DECLARATION OF CONFORMITY Motorola Inc., Connected Home Solutions, 101 Tournament Drive, Horsham, PA 19044, 1-215-323-1000, declares that t
5 TROUBLESHOOTING 42 Problem Possible Solution There is no video on the TV screen • Verify that the TV is powered on and set to the appropriate in