Motorola M68CPU32BUG Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 68
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
HARDWARE PREPARATION AND INSTALLATION
M68332BCC/D 2-12 MOTOROLA
REV 1
2.4 INSTALLATION INSTRUCTIONS
A user supplied power supply and RS-232C compatible terminal are required for BCC operation.
An RS-232C compatible host computer, with terminal emulation package, may be connected to
the BCC for S-record downloading.
2.4.1 Power Supply - BCC Interconnection
The BCC requires +5 Vdc @ 200 mA (max.) for operation. Use 18 to 20 AWG wire to connect a
user supplied power supply to the BCC. This connection is made via expansion connector P1 or
P2.
There are two preferred methods for connecting the power supply to the BCC: wire-wrap and
crimp-to-wire. When using the crimp-to-wire method, fabricate two wires (+5 Vdc and GND) as
follows:
a. Trim back 18 - 20 AWG wire approximately 0.25 inch.
b. Attach a crimp-to-wire receptacle (Dupont 46227-0000) to the wire using a crimping
tool.
c. Place heat shrink tubing (Digi-Key W183-ND) on the crimp-to-wire receptacle and
shrink using a heat source.
Connect the power supply ground fabricated wire to pin 1, 2, 63, or 64 of P1 or P2. Connect the
power supply +5 Vdc fabricated wire to pin 3, 4, 61, or 62 of P1 or P2 (as shown below).
GND
+5V
+5V
GND
GND
+5V
+5V
GND
1
3
5
59
61
63
2
4
6
60
62
64
P1/P2
Vue de la page 21