OPERATING INSTRUCTIONS
M68332BCC/D 3-10 MOTOROLA
REV 1
3.4.4 Diagnostic Monitor
The diagnostic monitor is a series of self-tests for the MC68332 MCU device. The diagnostic
monitor is programmed into the BCC EPROM. For more information on the diagnostic monitor,
refer to Chapter 6 of the M68CPU32BUG Debug Monitor User’s Manual,
M68CPU32BUG/AD1. The diagnostic monitor commands are:
• HE (help) command displays a menu of the top level directory.
• ST (self test) command executes self-test diagnostics.
• SD (switch directories) command toggles between the CPU32Bug directory and the
CPU32Diag directory.
• LE (loop-on-error) endlessly repeats a test at the point where an error is detected.
• SE (Stop-On-Error) halts a test at the point where an error is detected.
• LC (loop-continue) endlessly repeats a test or series of tests.
• NV (non-verbose)suppresses all error messages except PASSED or FAILED.
• DE (display error counters) displays the results of a particular test.
• ZE (clear error counters) resets all error counters to zero.
• DP (display pass count) is the number of passes in loop-continue mode. Under this
command the count is displayed with other information at the conclusion of each
pass.
• ZP (zero pass count) resets the pass counter to zero.
Available utilities are:
– WL - Write Loop
– RL - Read Loop
– WR - Read/Write Loop
CPU tests are a series of diagnostics provided to test the CPU portion of the MC68332
MPU:
– CPU A - Register Test
– CPU B - Instruction Test
– CPU C - Address Mode Test
– CPU D - Exception Processing Test
Commentaires sur ces manuels