OPERATING INSTRUCTIONS
M68332BCC/D 3-10 MOTOROLA
REV 1
3.4.4 Diagnostic Monitor
The diagnostic monitor is a series of self-tests for the MC68332 MCU device. The diagnostic
monitor is programmed into the BCC EPROM. For more information on the diagnostic monitor,
refer to Chapter 6 of the M68CPU32BUG Debug Monitor User’s Manual,
M68CPU32BUG/AD1. The diagnostic monitor commands are:
HE (help) command displays a menu of the top level directory.
ST (self test) command executes self-test diagnostics.
SD (switch directories) command toggles between the CPU32Bug directory and the
CPU32Diag directory.
LE (loop-on-error) endlessly repeats a test at the point where an error is detected.
SE (Stop-On-Error) halts a test at the point where an error is detected.
LC (loop-continue) endlessly repeats a test or series of tests.
NV (non-verbose)suppresses all error messages except PASSED or FAILED.
DE (display error counters) displays the results of a particular test.
ZE (clear error counters) resets all error counters to zero.
DP (display pass count) is the number of passes in loop-continue mode. Under this
command the count is displayed with other information at the conclusion of each
pass.
ZP (zero pass count) resets the pass counter to zero.
Available utilities are:
WL - Write Loop
RL - Read Loop
WR - Read/Write Loop
CPU tests are a series of diagnostics provided to test the CPU portion of the MC68332
MPU:
CPU A - Register Test
CPU B - Instruction Test
CPU C - Address Mode Test
CPU D - Exception Processing Test