Motorola M12 Oncore Spécifications Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 147
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
VP ONCORE COMMAND REFERENCE
GMT CORRECTION (@@Ab)
Motorola Binary Format
Input Command Query Current GMT Offset:
@@Ab
xxxC<CR><LF>
xxx - $ffffff (three bytes, all hex $ff)
C – checksum
Message length: 10 bytes
Change current GMT Offset:
@@Ab
shmC<CR><LF>
s - sign 00 = positive
ff = negative
h - hours 0 .. 23
m - minutes 0 .. 59
C - checksum
Message length: 10 bytes
Response Message (To either command):
@@AbshmC<CR><LF>
s - sign 00 = positive
ff = negative
h - hours 0 .. 23
m - minutes 0 .. 59
C - checksum
Message length: 10 bytes
10 Synergy Systems, LLC 05OCT01
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 146 147

Commentaires sur ces manuels

Pas de commentaire