8 Symbol MiniScan Family of Scanners
Triggering Options
Level Trigger
The laser is enabled and decode processing begins when
the trigger line is activated. Decode processing continues
until a good decode occurs, the trigger is released, or the
Laser-On time expires. The laser is disabled once decode
processing is complete. The next decode attempt does
not occur until the trigger line is released and then
reactivated.
Level
Pulse Trigger
The laser is enabled and decode processing begins when
the trigger line is activated. The laser remains on and
decode processing continues regardless of the trigger line
until a good decode occurs, or until the Laser-On time
expires. The laser is disabled once decode processing is
complete. The next decode attempt does not occur until
the trigger line is released and then reactivated.
Pulse
Vue de la page 7