Motorola AT Commands G24-L Informations techniques Page 80

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 106
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 79
Environmental Specifications
54 G24-L Module Hardware Description November 15, 2008
Environmental Specifications
Table 3-2 gives the environmental operating conditions of the G24-L module.
Caution: Exceeding the values may result in permanent damage to the module.
Application Interface Specifications
Table 3-3 summarizes the DC electrical specifications of the application interface connector
signals.
Important: Interface signals that are not used by the customer application must be left
unconnected. G24-L incorporates the necessary internal circuitry to keep
unconnected signal in their default state. Do not connect any components to, or
apply any voltage on, signals that are not used by the application.
Important: Signals that are defined as "Do Not Use", or DNU, must remain externally
unconnected in any case. These signals are reserved for future use.
Table 3-2: Environmental Ratings
Parameter Conditions Min Max Unit
Standard Operating
Temperature
-20 +75 °C
Storage Temperature -40 +85 °C
ESD At antenna connector
Air
Contact
At interface connector
± 15
± 6
± 1
KV
Vue de la page 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 105 106

Commentaires sur ces manuels

Pas de commentaire