BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks
68P80401P01-O 5-3
4. Wipe and dry the unit with a soft, absorbent, lint-free cloth. Make sure that there are no damp
spots on the connectors or in cracks and crevices.
5.5 Mechanical and Electrical Checks
Before conducting more complex tests, clean and check the unit for any mechanical defects that
might cause or contribute to the problem.
The following tests constitute the mechanical and electrical consistency of the unit:
Shock and Pressure
SIM Card Swap
Accessory Swap
Lockup
Battery Connections
GPS Receiver
Voltage Recognition
Camera Test
Bluetooth Hands Free
Shock and Pressure Test
Use this test to determine if controlled shock and pressure can repeat a reset or intermittent contact
condition.
NOTE: Perform this test with the rear housing securely in place and antenna completely pushed
in.
The Shock and Pressure test time is approximately 3 minutes:
1. Power up the unit.
2. Throw the unit into the palm of your hand alternating the front, sides, and back of the unit.
Check if the unit turns off, displays “Reset,” or status LED (if so equipped) turns to red. Then,
continue to the next step.
3. Apply pressure to the front, sides, and back of the unit with your thumbs. Never apply direct
pressure to any display or lens area.
If unit turns off, displays “Reset,” or status LED (if so equipped) turns to red, retry this test with
a battery known to be in good working condition. Verify that the contacts in the unit and on the
battery are clean.
4. Start test again. If the reset/intermittent contact condition persists, power down the unit and
send to your iDEN Customer Support Center.