BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks
5-4 68P80401P01-O
5.5.1 SIM Card Swap Test
Use this test to determine if the SIM card is defective, or if the unit is defective.
The SIM Card Swap test time is approximately 5 minutes:
1. Power off the unit, and then remove the battery.
2. Remove the SIM card from the unit.
3. Clean the SIM card, if necessary, by wiping its surfaces with a clean, static-free cloth, and then
check the contact areas in the unit for foreign material, damage, or other defects.
4. Replace the SIM card with the test (reference) SIM card. Ensure the test SIM card is clean.
5. Power on the unit, and verify that the test SIM card works with the unit.
If the unit works, the customers SIM card is defective and should be replaced, or the problem is
due to operator error, system, or carrier. If the unit does not work, the unit is defective and
should be sent to the iDEN Radio Support Center.
NOTE: If a defective SIM card is replaced with a new card or test card, all personal
information (voice notes, datebook entries, etc.) that was stored on the original card
will be lost.
6. Install the customers SIM card in a test (reference) unit.
If the test unit works, the customers unit is defective and should be sent to the iDEN Radio
Support Center
5.5.2 Accessory Swap Test
Use this test to determine if the unit’s accessories are defective.
NOTE: When adding or removing accessories, the main screen displays “Device Attached” or
“Device Detached” and the external screen displays a similar message.
The Accessory Swap test time is approximately 5 minutes:
1. Remove the accessory and check the contact areas for foreign material, damage, or other
defects.
2. Replace the problem accessory with the reference accessory.
3. Verify the reference accessory works with the unit.
If the reference accessory works, the customers accessory is defective and should be replaced.
4. Verify the customers accessory works with a reference unit.
If the accessory works, the customers unit is defective and should be sent to the iDEN Radio
Support Center.