Motorola Phaser P460 Instructions d'exploitation Page 147

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 208
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 146
5-88
P460/P360 Memory Scanners Product Reference Guide
Macro PDF Transmit / Decode Mode Symbols
Select only one of the four options below for handling the decoding of Macro PDF. The
scanner can handle up to 64K bytes of decoded data, including any optional field
information, except in the modes Transmit Any Symbol in Set/No Particular Order and Scan
in Sequence Only/Transmit in Sequence Without Buffering where there is no limit to the
size of the Macro PDF set.
!
Buffer All Symbols / Transmit When Complete - transmits entire Macro PDF
sequence after all the symbols are scanned. This is the default option.
If the decode data exceeds the limit of 64 symbols or 64K bytes, there is no
transmission because the entire sequence has not been scanned. Use the
parameter Flush Macro PDF Buffer to purge the buffer.
!
Transmit Any Symbol in Set / No Particular Order - causes transmission of data
from up to 1024 Macro symbols as decoded, whether it is in sequential order or not.
!
Scan in Sequence Only / Transmit in Sequence Without Buffering - causes
transmission of data from up to 1024 symbols within the Macro PDF sequence as
decoded, provided the Macro PDF symbols are scanned in order. If you do not
scan the symbols in order, an error occurs.
!
Buffer Scans Out of Order / Transmit Scans in Order - when enabled, decode
data from each symbol within the Macro PDF sequence is transmitted when
decoded, provided that the Macro PDF symbols are scanned in order. Decode data
from symbols out of order in the Macro PDF sequence is buffered. The scanner can
buffer up to 64 symbols or 64K bytes.
Vue de la page 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 207 208

Commentaires sur ces manuels

Pas de commentaire