Motorola CPCI-6115 Manuel de service Page 170

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 196
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 169
Memory Maps and Addresses
CPCI-6200 Installation and Use (6806800J66C)
170
The prescaler provides the clock required by each of the four timers. The input clock to the
prescaler is 25 MHz. The default value is set for $E7 which gives a 1 MHz reference clock for a
25 MHz input clock source.
7.4.27.2 Control Registers
Tick Timer 1 Control Register–0xF202_0010 (32 bits)
Tick Timer 2 Control Register–0xF202_0020 (32 bits)
Tick Timer 3 Control Register–0xF202_0030 (32 bits)
Tick Timer 4 Control Register–0xF202_0040 (32 bits)
Table 7-54 Tick Timer Control Registers
Bit Field Operation Reset
31:11 RSVD R 0
10 INTS R 0
9CINT R/W0
8EN_INTR/W0
7OVF R 0
6
5
4
3RSVDR 0
2COVFR/W0
1COC R/W0
0ENC R/W0
Table 7-55 Tick Timer Control Field Definition
RSVD Reserved
INTS Interrupt Status
CINT Clear Interrupt
Vue de la page 169
1 2 ... 165 166 167 168 169 170 171 172 173 174 175 ... 195 196

Commentaires sur ces manuels

Pas de commentaire